top | item 38922483

(no title)

ooboe | 2 years ago

The 4 bolts are there to restrain vertical motion of the door which I presume would not involve large forces. They are meant to keep the door on the 4 cylindrical posts and 12 stop pads and it is those posts and pads that take the pressure differential forces on the door and keep it from blowing out. They are way beefier than the bolts and I believe they are still intact on the accident plane.

discuss

order

albert_e|2 years ago

do some of these bolts also carry the weight of the door?

what if the springs on the lower hinges (that are supposed to keep an upward pressure on the door, supporting its weight) are weaker than necessary or somehow failed and went unnoticed... would that put too much burden on the bolts and other fastening mechanisms and cause them to fail in turn over time?