(no title)
knotimpressed | 6 months ago
If I'm making my own 18650 USB C power banks, are there any easy to miss risks? I've got the cells in holders, not welded, but the holders are specc'd above the current I need. The cells are unprotected, but the Aliexpress listing for the power management board says specifically to use unprotected cells, as at 6A draw most protection boards don't do well (dubious). The cells are tested and mechanically protected by a thick enclosure. The only EE work I'm doing is soldering 2 high gauge wires from the holder to the board that's doing everything else. I know Aliexpress isn't a bastion of quality, but the seller has good feedback and I checked over the board to make sure there's at the very least a good counterfeit battery protection IC included.
Currently, the concerns I have are: - the holder relies on good contact to deliver 6A without developing hotspots on the terminals - the board from Aliexpress perhaps should not be trusted
If there's anything else anyone can think of, I'm happy to hear it.
Cyan488|6 months ago
Without the design files, running a failure modes and effects analysis on the board is difficult.
There's also no guarantee that each board you get is built identically. Some parts or the whole design could be changed between orders.
If I was designing a power bank board professionally, I'd be putting it through the ringer - environmental, mechanical, component level short circuit, load short circuit, load power injection, input over-voltage, input transient, RFI/EMI susceptibility, etc. Do you trust that all that has been done on a board that is representative of what you've received?
Panzer04|6 months ago
Beyond short circuit/overcurrent, overtemp, over voltage, under voltage protections, what else would be necessary to ensure safe usage of the cells from an electrical perspective? Ie. What additional protections would a batter management circuit need to be safe in normal circumstances?
knotimpressed|6 months ago
As another commenter said, is there anything beyond short circuit/overcurrent for the load side, and undervoltage/overcurrent protection on the cell side that’s crucial for a non professional bank? I’m happy to pop a few boards testing them myself.
ranger207|6 months ago
knotimpressed|6 months ago
Eduard|6 months ago
knotimpressed|6 months ago